1-877-780-2131
Special Offers - Limited Time - Limited Quantities - Click for Details
Printer icon Print This Page
Acrobat icon Acrobat Reader
Required to view PDF files
Flash icon Flash Player
Required to view videos
Lynx Gage
Lynx Gage

The Lynx Gage gives you the same adjustment technology as the Panther Gage, but at a lower cost. Its one button interface makes it simple to operate. Turn and click a few times and you're ready to go.

Two shutdown options allow confident unattended running. If you want scrag reducing performance at a lower cost and SPC is not an issue, the Lynx gage is for you.

The bright, multi-function meter can display the current production performance several different ways for easy monitoring. You can tell from a distance if something needs your attention.

  • Easy, one button interface
  • Precise adjustments reduce scrag
  • Multi-function meter monitors performance
  • Temperature stability holds length over time
  • Lot size counter
  • Unsurpassed reliability reduces down time
  • Lower cost
  • Automatic shutdown on two different events: Consecutive Bad / No Cutoff
General Specifications
Resolution 0.0001" (0.01 mm)
Operating Speed Up to 30,000 springs / hour
Input Power 120 / 240, 50/60 Hz, 2A max
Sort / Adjust Output Voltages 120 VAC (100 W), 24 VAC (48 W), 24 VDC (24 W)
Height 6.5" (165 mm)
Width 10.6" (269 mm)
Depth 9.2" (234 mm)
Weight 8 lb (3.6 kg)

Lynx software version level is displayed when the gage is turned on. The meter will flash the software version using the numbered lights on the multifunction meter. For example, if the Lynx flashes the 2 light then the 1 light, the software version is 2.1. Software upgrades are free. Software revision upgrades are free. Contact us if your Lynx needs an upgrade.

Lynx Software Revisions | Larson Systems Inc.
Software Revisions
Version Description
1.1 Original release.
1.2 Adjusted math for slight increase in accuracy.
1.3 Added version display to meter on power up.
Added delay to No Cutoff shutdown to stop accidental shutdowns.
1.4 Allowed probe zeroing with 1" tip.
1.5 Refined adjust time calculation.
Allowed probe setup further from spring.
Adjust point setup changed to 10%, 20%, 30%…
1.6 Stopped allowing illegal probe setups that were too close to the spring.
2.1 Scaled meter to set "5" and "25" to the sort points.
Reject springs display beyond these meter points.
Ordering Information
Part Number Description Price
Gage
025-0000-0641-00 Lynx Gage - 120 VAC In / 120 VAC (100W) Out Quote
025-0000-0641-01 Lynx Gage - 240 VAC In / 24 VAC (48W) Out Quote
025-0000-0641-02 Lynx Gage - 240 VAC In / 24 VDC (24W) Out Quote
When ordering your Lynx gage, please specify which faceplate you wish to use:
English, German, Mandarin Chinese or Spanish.
Probes - Click here for more info
025-0000-0658-02 PX595G Heated Probe (English) Quote
025-0000-0658-03 PX595G Heated Probe (Metric) Quote
Probe Tips - Click here for more info
018-0000-2535-00 Extended Probe Tip - 1/8 X 1", Threaded (3 x 25 mm) Quote
018-0000-2531-00 Extended Probe Tip - 1/4 X 1", Threaded (6 x 25 mm) Quote
018-0000-2532-00 Extended Probe Tip - 3/8 X 1", Threaded (9 x 25 mm) Quote
018-0000-2533-00 Extended Probe Tip - 5/8 X 1", Threaded (16 x 25 mm) Quote
018-0000-2534-00 Extended Probe Tip - 1 X 1", Threaded (25 x 25 mm) Quote
025-0000-0654-00 Extended Probe Tip - Base Assembly, Threaded Quote
025-0000-0655-00 Extended Probe Tip - Kit (1 Base & 5 Tips) Quote
025-0000-0631-00 Probe Tip Assembly, 1/8" diameter Quote
025-0000-0631-01 Probe Tip Assembly, 1/4" diameter Quote
025-0000-0631-02 Probe Tip Assembly, 3/8" diameter Quote
025-0000-0631-03 Probe Tip Assembly, 5/8" diameter Quote
025-0000-0631-04 Probe Tip Assembly, 1" diameter Quote
025-0000-0655-01 Extended Probe Tip - Kit (5 single piece assemblies) Quote
Guarded Probe Tips - Click here for more info
025-0000-0597-03 Guarded Probe Tip - 5/8" Dia. (16 mm) Quote
025-0000-0597-00 Guarded Probe Tip - 1.0" Dia. (25 mm) Quote
025-0000-0597-01 Guarded Probe Tip - 1.5" Dia. (38 mm) Quote
025-0000-0597-02 Guarded Probe Tip - 2.0" Dia. (52 mm) Quote
Probe Holders - Click here for more info
025-0000-0640-00 PB309B - Fixed Probe Holder Quote
025-0000-0679-00 Manual Swing-Away Probe Holder Quote
025-0000-0573-00 RP2 - Retractable Probe Holder Quote
ASR1 Sorting Devices - Click here for more info
025-0000-0600-00 ASR1 - Two-Way Air Jet, 120 VAC (100W) Quote
025-0000-0600-02 ASR1 - Two-Way Air Jet, 24 VAC (48W) Quote
025-0000-0600-01 ASR1 - Two-Way Air Jet, 24 VDC (24W) Quote
MC34 Sorting Devices - Click here for more info
025-0000-0566-00 MC34-2 - Two-Way Pneumatic Sorter, 120 VAC (100W) Quote
025-0000-0566-02 MC34-2 - Two-Way Pneumatic Sorter, 24 VAC (48W) Quote
025-0000-0566-01 MC34-2 - Two-Way Pneumatic Sorter, 24 VDC (24W) Quote
MC46 Sorting Devices - Click here for more info
025-0000-0538-00 MC46-3 - Three-Way Pneumatic Sorter, 120 VAC (100W) Quote
025-0000-0538-02 MC46-3 - Three-Way Pneumatic Sorter, 24 VAC (48W) Quote
025-0000-0538-01 MC46-3 - Three-Way Pneumatic Sorter, 24 VDC (24W) Quote
025-0000-0537-00 MC46-5 - Five-Way Pneumatic Sorter, 120 VAC (100W) Quote
025-0000-0537-02 MC46-5 - Five-Way Pneumatic Sorter, 24 VAC (48W) Quote
025-0000-0537-01 MC46-5 - Five-Way Pneumatic Sorter, 24 VDC (24W) Quote
SC48 Sorting Devices - Click here for more info
025-0000-0576-00 SC48-3 - Three-Way Electric Sorter with Stand, 120 VAC (100W) Quote
025-0000-0582-00 SC48-3AP - Three-Way Pneumatic Sorter with Stand, 120 VAC (100W) Quote
025-0000-0582-02 SC48-3AP - Three-Way Pneumatic Sorter with Stand, 24 VAC (48W) Quote
025-0000-0582-01 SC48-3AP - Three-Way Pneumatic Sorter with Stand, 24 VDC (24W) Quote
025-0000-0578-00 SC48-5 - Five-Way Electric Sorter with Stand, 120 VAC (100W) Quote
025-0000-0580-00 SC48-5AP - Five-Way Pneumatic Sorter with Stand, 120 VAC (100W) Quote
025-0000-0580-02 SC48-5AP - Five-Way Pneumatic Sorter with Stand, 24 VAC (48W) Quote
025-0000-0580-01 SC48-5AP - Five-Way Pneumatic Sorter with Stand, 24 VDC (24W) Quote
Read Switches - Click here for more info
025-0000-0648-00 RS2E Read Switch Quote
025-0000-0648-01 Magnetless Read Switch Quote
Shutdown Control - Click here for more info
025-1000-0426-00 Shutdown Cable Quote
025-0000-0652-00 Shutdown Bypass Connector Quote
Pitch Adjust Motors - Click here for more info
025-0000-0589-00 AC336 Motor - For use on coilers with up to 1/2" pitch rods Quote
025-0000-0596-00 AC337 Heavy Duty Motor - For use on coilers with up to 3/4" pitch rods Quote
Miscellaneous Items
025-1000-0425-00 Cable Assembly: 2 Pin Bendix 8' Quote
025-1000-0424-00 Cable Assembly: Sorting Chute, 3 Pin Quote
025-1000-0461-00 Cable Assembly: Controller Motor, 3 Pin 2-Con Quote
025-1000-0452-00 Cable Assembly: 5 Way Sorter, 6 Pin Bendix 7' with Ground Quote
025-1000-0206-00 Conn Bendix, 6 Pin Male, Cord End Quote

Top icon
Larson Systems Inc.
13847 Aberdeen Street NE
Ham Lake, MN 55304
Phone: 763-780-2131
Fax: 763-780-2182
Top icon
LarsonSystems.com    |    SpringTesters.com    |    SpringGages.com