Home > Products > Tester Upgrades > Carlson MET-SF Series Upgrade

Carlson MET-SF Series Upgrade

Standard Features
  • 2 point with rate
  • Load / length limits
  • Deflection compensation
  • Complete LSI upgrade including paint, length measurement and electronics
  • Completely refurbished mechanically; better than new
  • 12 month warranty
  • NIST traceable calibration
MET-SF Upgrade



Full Custom Options List
(U.S. Pricing Only)


Larson Systems Inc. has made the commitment to repair, upgrade and calibrate Carlson MET-SF Series, Carlson MET-MF Series and the Reicherter line of testers. In many cases we can repair the testers to OEM specifications. In occasions when OEM repair is not available or economically feasible We have several unique repair / upgrade options at some surprisingly affordable prices. In addition, we offer a high quality Polane paint job to finally finish the job since the factory never painted the original tester. It will look like new!

Our factory calibration includes NIST traceable certification of force, length, parallelism and deflection compensation.

DHT Force Upgrade - 050-0000-0085-02
Original Carlson MET-SF Series
DHT Force Upgrade
Upgrade with Paint
(018-3000-0021-00)
MET-SF Series original
MET-SF Series with DHT Force Upgrade
MET-SF Series with DHT Force Upgrade and Paint
LSI DHT electronics package replaces the existing electronics. This package contains features like digital final calibration and linearization, push button force zeroing, backlit LCD display, English and metric units, tracking and optional peak force readings.

Optional: 4-6 hr Ni Cad Battery operation, Length upgrade, RS-232 printer or data logger output.

DHT Force / Length Upgrade - 050-0000-0085-01
Original Carlson MET-SF Series
DHT Force / Length Upgrade
Upgrade with Paint
(018-3000-0021-00)
MET-SF Series original
MET-SF Series with DHT Force and Length Upgrade
MET-SF Series with DHT Force and Length Upgrade and Paint
LSI DHT electronics package replaces the existing electronics. This package contains load cell and frame deflection compensation. This means no more look up tables to get correct length readings. What the display says is always correct.

Other features are: digital display of length and force. There is no more messing around with a dial indicator, digital final calibration and linearization, push button force zeroing, backlit LCD display, wipe clean membrane switch pad, English and metric units, tracking and peak force readings.

Optional: 4-6 hr Ni Cad Battery operation, RS-232 printer or data logger output


SDHT Force / Length Upgrade - 050-0000-0085-00
Original Carlson MET-SF Series
SDHT Force / Length Upgrade
Upgrade with Paint
(018-3000-0021-00)
MET-SF Series original
MET-SF Series with SDHT Force and Length Upgrade
MET-SF Series with SDHT Force and Length Upgrade and Paint
LSI SDHT electronics package replaces the existing electronics. This is a premier computer package with available software upgrades like 2 Point with Rate software, Limit Lights and Full Statistical Analysis, Calculated Free length Measurement, Initial Tension Measurement and Peak Test Mode.

This package contains load cell and frame deflection compensation. This means no more look up tables to get correct length readings. What the display says is always correct.

Other features are: digital display of length and force. There is no more messing around with a dial indicator, total digital calibration and linearization, push button force zeroing, backlit LCD display, wipe clean membrane switch pad, English and metric units, tracking and peak force readings.

Optional: 4-6 hr Ni Cad Battery operation, RS-232 printer or data logger output.

DHT - Force Specifications
 
SDHT - Force Specifications
Capacity Resolution Capacity Resolution

0-20% FS*
0-100% FS
20-100% FS*
0-20% FS 20-100% FS
2 lb 0.0001 lb 0.001 lb 2 lb 0.00002 lb 0.0002 lb
907 g 0.02 g 0.2 g 907 g 0.01 g 0.1 g
8.9 N 0.0002 N 0.002 N 8.9 N 0.0001 N 0.001 N
11 lb 0.0005 lb 0.005 lb 11 lb 0.0002 lb 0.002 lb
5 kg 0.0002 kg 0.002 kg 5 kg 0.1 g 1 g
49 N 0.002 N 0.02 N 49 N 0.001 N 0.01 N
22 lb 0.001 lb 0.01 lb 22 lb 0.0005 lb 0.005 lb
10 kg 0.0005 kg 0.005 kg 10 kg 0.2 g 2 g
98 N 0.005 N 0.05 N 98 N 0.002 N 0.02 N
66 lb 0.002 lb 0.02 lb 66 lb 0.001 lb 0.01 lb
30 kg 0.001 kg 0.01 kg 30 kg 0.5 g 5 g
294 N 0.01 N 0.1 N 294 N 0.005 N 0.05 N
Accuracy = ± Resolution x 2
*Requires 050-0000-0107-00 - For High Force Resolution
Accuracy = ± Resolution x 2

Tester Upgrades - Length Specifications
Capacity Standard Resolution
Resolution Accuracy (±)
All 0.0005 in 0.001 in
0.01 mm 0.02 mm

 